Matches in Data.gov.be for { <http://data.gov.be/.well-known/genid/dataset/kulrdr/doi-10-48804/VY7A2T> ?p ?o ?g. }
Showing items 1 to 30 of
30
with 100 items per page.
- VY7A2T accessRights PUBLIC @default.
- VY7A2T bibliographicCitation "Wellens, Jolan, 2025, "Data for paper: Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., McLaughlin, M., Verhaert, N., & Bartic, C. (2025). Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection. Sensors and Actuators B: Chemical, 137789. https://doi.org/10.1016/j.snb.2025.137789", https://doi.org/10.48804/VY7A2T, KU Leuven RDR, V1" @default.
- VY7A2T created "2025-07-02T09:46:30Z" @default.
- VY7A2T creator 0000-0003-1561-4593 @default.
- VY7A2T description "Dieser enthält alle Daten, die zur Erstellung der Zahlen im Papier verwendet werden, sowie ergänzende Informationen zu: Wellens, J. et al., Wasserstoffperoxid-Sensorik mit Cochlea-Implantaten in vivo: Auf dem Weg zur intraoperativen Traumaerkennung. Sensoren und Aktoren B: Chemisch, 137789. https://doi.org/10.1016/j.snb.2025.137789 Die Daten enthalten hauptsächlich elektrochemische Charakterisierungsdaten der IrOx-Referenzelektrode (Open-Circuit-Potential, Impedanz, ...) und der Wasserstoffperoxid-Sensorelektrode (Amperometrie, Impedanz). Zusätzlich werden AFM-Bilder zur Bestimmung von Rauheit und Dicke sowie Zellviabilität und Adhäsion aufgenommen." @default.
- VY7A2T description "Dit bevat alle gegevens die zijn gebruikt om de cijfers in het document samen te stellen en aanvullende informatie over: Wellens, J. et al., Waterstofperoxidedetectie met cochleaire implantaten in vivo: Op weg naar intraoperatieve traumadetectie. Sensoren en actuatoren B: Chemisch product, 137789. https://doi.org/10.1016/j.snb.2025.137789 De gegevens bevatten meestal elektrochemische karakteriseringsgegevens van de IrOx-referentie-elektrode (open circuitpotentiaal, impedantie, ...) en van de waterstofperoxidesensorelektrode (amperometrie, impedantie). Daarnaast worden AFM-beelden gebruikt voor de bepaling van ruwheid en dikte, evenals de levensvatbaarheid en hechting van cellen." @default.
- VY7A2T description "Il contient toutes les données utilisées pour construire les chiffres dans le document et des informations supplémentaires sur: Wellens, J. et al., Détection du peroxyde d'hydrogène avec implants cochléaires in vivo: Vers la détection des traumatismes intra-opératoires. Capteurs et actionneurs B: Produits chimiques, 137789. https://doi.org/10.1016/j.snb.2025.137789 Les données contiennent principalement des données de caractérisation électrochimique de l'électrode de référence IrOx (potentiel de circuit ouvert, impédance, ...) et de l'électrode de détection du peroxyde d'hydrogène (Amérométrie, impédance). En outre, les images AFM utilisées pour la détermination de la rugosité et de l'épaisseur, ainsi que la viabilité et l'adhérence des cellules sont incluses." @default.
- VY7A2T description "This contains all data used to construct the figures in the paper and supplementary information of: Wellens, J. et al., Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection. Sensors and Actuators B: Chemical, 137789. https://doi.org/10.1016/j.snb.2025.137789 The data mostly contains electrochemical characterization data of the IrOx reference electrode (Open circuit potential, impedance, ...) and of the hydrogen peroxide sensing electrode (Amperometry, impedance). Additionally AFM images used for determination of roughness and thickness, as well as cell viability and adhesion are included." @default.
- VY7A2T identifier "doi:10.48804/VY7A2T" @default.
- VY7A2T issued "2025-07-03T08:59:47Z" @default.
- VY7A2T modified "2025-07-03T08:59:47Z" @default.
- VY7A2T publisher 0419052173 @default.
- VY7A2T subject "(Bio)chemical engineering" @default.
- VY7A2T subject "(Bio)medical engineering" @default.
- VY7A2T subject "Basic sciences" @default.
- VY7A2T subject "Physical sciences" @default.
- VY7A2T title "Data for paper: Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., McLaughlin, M., Verhaert, N., & Bartic, C. (2025). Hydrogen peroxide sensing with cochlear implants in vivo: Towards intra-operative trauma detection. Sensors and Actuators B: Chemical, 137789. https://doi.org/10.1016/j.snb.2025.137789" @default.
- VY7A2T title "Daten für Papier: Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., McLaughlin, M., Verhaert, N., & Bartic, C. (2025). Wasserstoffperoxid-Sensorik mit Cochlea-Implantaten in vivo: Auf dem Weg zur intraoperativen Traumaerkennung. Sensoren und Aktoren B: Chemisch, 137789. https://doi.org/10.1016/j.snb.2025.137789" @default.
- VY7A2T title "Données pour le papier: Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., McLaughlin, M., Verhaert, N., et Bartic, C. (2025). Détection de peroxyde d'hydrogène avec implants cochléaires in vivo: Vers la détection des traumatismes intra-opératoires. Capteurs et actionneurs B: Produits chimiques, 137789. https://doi.org/10.1016/j.snb.2025.137789" @default.
- VY7A2T title "Gegevens voor papier: Wellens, J., Kerkhofs, L., Deschaume, O., Putzeys, T., Franceschini, F., Taurino, I., Wagner, P., McLaughlin, M., Verhaert, N., & Bartic, C. (2025). Waterstofperoxidedetectie met cochleaire implantaten in vivo: Op weg naar intraoperatieve traumadetectie. Sensoren en actuatoren B: Chemisch product, 137789. https://doi.org/10.1016/j.snb.2025.137789" @default.
- VY7A2T citedBy genid68085 @default.
- VY7A2T type Dataset @default.
- VY7A2T contactPoint genid68086 @default.
- VY7A2T keyword "Cochlear implants" @default.
- VY7A2T keyword "Electrochemical sensing" @default.
- VY7A2T keyword "Hydrogen peroxide" @default.
- VY7A2T landingPage VY7A2T @default.
- VY7A2T theme HEAL @default.
- VY7A2T theme TECH @default.
- VY7A2T version "1" @default.